Water

Target User:

  • Treatment plants for drinking water, sewage and industrial discharges
  • water analysis laboratories, production and supply of drinking water

 

Target Application:
Gravimetrical analysis of organic and inorganic impurities in water and waste water. Monitoring microbiological contaminants in drinking water.

OBJECTIVE

TECHNIQUE

TYPE of FILTER

PART NUMBER-GRADE

Sample preparation

Clarification

Qualitative filter paper

DF 595

Determination of separable compounds 13)

Filtration weighing

Glass micro fibre

GF 6

Filter paper, quantitative analysis

589/1

Measurement of solids in suspensions after drying at 105ºC 1) 2) 3)

Filtration, Weighing

Glass microfibre filter

GF 52

GF 6

Measurement of the total remainder after drying at 180ºC 4) 5)

GF 52

GF 6

Solids and volatiles after incineration at 550ºC 6)

GF 50

Floatable particles 7)

GF 52, GF 6

Coloration 2)

Filtration

GF 6, GF 50

Radioactivity of  water

Measurement of metals

Measurement of total and dissolved organic carbon 8) 9) 10)

Filtration, Combustion-infrared

0.45 µm cellulose acetate/ mixed cellulose ester

AC 045

MCE 045

Filtration, Oxidation

Glass microfibre filter

GF 6, GF 52

Measurement of dissolved iron 2)

Filtration

0.45 µm cellulose acetate

AC 045

Measurement of metals

(pre-filtration) 11)

Filtration, Atomic absorption spectrometry

0.45 µm cellulose acetate

AC 045

Measurement of oils and fats 12)

Buchner funnel

Filter paper quantitative analysis

589/5

Measurement of metals

589/1, 589/3

Testing radioactivity of water 14)

Precipitation (Ra)

0.45 µm cellulose acetate

AC 045

Measurement of non-metallic inorganic compounds 15)

Filtration

Filter paper quantitative analysis

589/1, 589/3

589/5

Measurement of oils and fats 12)

Extraction with Soxhlet Tecator

Cellulose extraction cartridges

900

901

Microbiological analysis of drinking water

Filtration

Sterile cellulose mixed ester

0.2 / 0.45 µm, white, gridded

MCES 020 47 BC

MCES 045 47 BC

Sterile cellulose nitrate membranes, 0.2 µm or

0.45 µm, white, gridded,

 

even as monitor (E-)

NCS 020 50 BC

NCS 020 47 BC

NCS 045 50 BC

NCS 045 47 BC

ENCS 045 47 BC

Microbiological analysis of drinking water, legionella

Sterile cellulose nitrate membrane, 0.45 µm, black, gridded,

even as monitor (E-)

NCS 045 47 NC

 

ENCS 045 47 NC

 

1) DIN EN 872:2005 Water quality, determination of suspended solids

2) Council Directive 79/869/CEE, of October 9, 1979, concerning the methods of measurement and frequencies of sampling and analysis of surface water intended for production of drinking water in the Member States

3) 2540 D Standard Methods for total suspended solids dried at 103-105°C

4) UNE 77031:1982 Analysis methods for industrial discharges

5) 2540 C Standard Methods for total dissolved solids dried at 180°C

6) 2540 E Standard Methods for fixed and volatile solids ignited at 550°C

7) 2530 B Standard Methods for particulate floatables, which depends on the gravity separation of particles having densities less than that of the surrounding water

8) UNE EN 1484:1997 Water analysis for the determination of total organic carbon (TOC) and dissolved organic carbon  (DOC)

9) 5310 B Standard Methods; high temperature combustion methods

10) 5310 D Standard Methods; wet oxidation methods

11) 3030 B Standard Methods; filtration for dissolved and suspended metals

12) UNE 77037:1983; water analysis methods in industrial wastes. Determination of oil and fats, total recoverable. Soxhlet extraction method

13) DIN 38409 German standard methods for the examination of water, waste water and sludge

14) 7500-Ra B Standard Methods for the determination of radium by precipitation

15) Part 4000 Standard Methods

16) DIN 38409 H2-2 German standard methods for the gravimetric determination of filterable substances through paper filters