大气排放
目标应用:
监测人为大气排放源(炼油厂、发电站、液态与固态燃料燃烧、水泥厂、采矿业、焚烧炉、铸铁厂、磨料厂、沥青厂、玻璃制造厂、陶瓷厂)。
放射性气溶胶沉降监测
发电厂及钢铁行业燃烧空气监测
工作场所与生产过程粉尘释放测量,民用住宅废气排放监测,新型发动机(汽车及其他车辆)尾气排放检测
目标用户:
排放行业环境管理部门
自治区及市议会环境部门
发动机制造商研发部门
| OBJECTIVE | APPARATUS | TECHNIQUE | TYPE of FILTER | PART NUMBER |
|---|---|---|---|---|
| Determination of suspended particles TSP (Ø >30mm)1, 4 | High volume collector | Gravimetry | Glass microfibre filter | GF 50 150 GF 50 203254 |
| Low volume capturer | GF 50 047 | |||
| Cascade impactor | GF 50 203254 | |||
| Determination and analysis of PM10 (Ø > 10mm)1, 2, 5 | High volume capturer | Quartz microfibre filter | QFH 150 QFH 203254 | |
| Low volume capturer | QFH 047 | |||
| Cascade impactor | QFH 203254 | |||
| Determination and analysis of PM2.5 (Ø >2.5mm)1, 3 | High volume capturer | Quartz microfibre filter | QFH 150 QFH 203254 | |
| Low volume capturer | QFH 047 | |||
| Cascade impactor | QFH 203254 | |||
| Determination and analysis to detect lead6, 7 | High volume capturer | Atomic absorption spectroscopy | Quartz microfibre filter | QFH 150 QFH 203254 |
| Low volume capturer | QFH 047 | |||
| Cascade impactor | QFH 203254
|
[Translate to 中文 (CN):] 1) Reference methods for TSP PM10, PM2,5 and Pb (lead) are codified in 40CFR50 Appx B, J, L, and G in the Federal Register of the US EPA (Environmental Protection Agency)
2) Air quality - Determination of the PM10 fraction of suspended particulate matter - Reference method and field test procedure EN12341
3) Ambient air quality - Standard gravimetric measurement method for the determination of the PM2.5 mass fraction of suspended particulate matter EN14907:2005 (German version)
4) Council Directive 80/779/EEC of July 15, 1980, on air quality limit values and guidance levels for sulphur dioxide and suspended particles. Incorporated into Spanish legislation by Royal edict1613/1985.
5) Council Directive 2008/50/EG, of June 11, 2010, related to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, fine dust up to 10 µm (PM 10) and 2,5 µm (PM 2.5) and lead in ambient air. Reference method described in European Standard EN12341.
6) Council Directive 2008/50/EG, of June 11, 2010, related to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air. Reference method described in ISO 9855: 1993.
7) Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter; German version EN 14902:2005